Interior calculator

Room HVAC Load Planning Calculator

Build a transparent preliminary sensible heating or cooling load range from envelope, windows, infiltration, occupants, and internal gains.

Project inputs

Enter your measurements

Core project inputs are shown. Current defaults are used for purchasing, product, and cost assumptions.

deg F
deg F
BTU/hr-ft2-F
BTU/hr-ft2-F
ACH

Conditioned rooms

1 section
Conditioned room 1
Room length
Room width
Room height
ft2
ft2

Planning estimate only. Verify dimensions, product specifications, site conditions, prices, ordering rules, and local codes with qualified professionals and suppliers.

How to use the hvac load planning calculator

  1. Measure the actual project. Break irregular work into separate sections and record finished dimensions consistently.
  2. Enter the core measurements. The quick view focuses on project geometry; add or subtract sections where the calculator supports multiple areas.
  3. Review purchasing assumptions. Open Advanced inputs to replace example prices, waste, coverage, density, pack size, minimum order, or delivery assumptions with current project information.
  4. Calculate and verify. Review the formula, limitations, whole-unit rounding, product instructions, and supplier requirements before purchasing.

Key inputs covered: Load planning mode, Indoor design temperature, Local outdoor design temperature, Opaque-envelope planning U-factor, Window planning U-factor, Infiltration air changes, Sensible gain per occupant, Lighting/appliance sensible gains, Planning range allowance, Room length, and additional project-specific assumptions.

Result coverage: The hvac load planning calculator reports 8 separate quantities so the primary estimate and its supporting purchase or planning values can be checked together.

How the estimate works

Envelope loads use area x entered U-factor x indoor/outdoor design-temperature difference; infiltration uses volume x ACH x 0.018 x temperature difference, with sensible people/watt gains added in cooling mode.

Changing outdoor design temperature changes the temperature difference and every transmission/infiltration component; it is not a preset climate-zone multiplier.

Assumptions, rounding, and limitations

Dimensions are treated as finished measurements. Only deductions and allowances entered above are included. Decimal measurements display to two places; purchase quantities round up when a whole container or piece is required.

  • This transparent screening model is not ACCA Manual J, approved load software, final equipment sizing, latent-load analysis, or duct design.
  • It omits orientation-specific solar gain, humidity, ground/crawlspace detail, duct loads, ventilation, thermal bridges, schedules, diversity, and many assembly inputs.
  • Use current local design weather and have a qualified HVAC professional perform Manual J and Manual S before equipment selection.

Sources and review

These references support unit conversions and selected planning assumptions. Product instructions and local requirements control the actual project.

Last reviewed: 2026-10-09

Editorial process

BuildPlanCalc publishes the formula, editable assumptions, limitations, and supporting references so the estimate can be checked rather than treated as a black box. See the calculation and review methodology, or report a correction.

Frequently asked questions

Are the results exact?

No. Results are planning estimates based on the dimensions and assumptions entered. Confirm product coverage, site conditions, and ordering rules with the supplier.

Related calculators